UK solar PV and heat pump calculators, with guides, on one server. Follows the MCS methods. No key.

No review yet · 0 questions Write a reviewAsk the authorFollow this entry

Is this your project? Claim this entry to answer questions, hear about reviews and appear as the author.

All projects by ampworth.com

Website
ampworth.com/developers
Server address
https://ampworth.com/mcp (streamable-http)
Version
1.0.20261017
Author
ampworth.com (namespace verified by the registry)
Source
Official MCP registry (updated Oct 17, 2026)

Reviews

No review yet.

Sign in to leave a review. Your email is all you need.

Questions for the author

No question yet.

Sign in to ask the author a question. The author has not claimed this entry yet: they will only be told if they claim it. Other members can answer.

Continue with GoogleGet a link by email

How to install it

Claude Code

In a terminal:

claude mcp add --transport http ampworth https://ampworth.com/mcp
Claude (app and claude.ai)

Open Settings, then Connectors, and add a custom connector with this address. If the server asks you to sign in, Claude will walk you through it.

https://ampworth.com/mcp
ChatGPT

In Settings, Apps & Connectors section, turn on developer mode, then create a connector with this address.

https://ampworth.com/mcp
Cursor ~/.cursor/mcp.json

Add this to ~/.cursor/mcp.json (or .cursor/mcp.json in the project):

{
  "mcpServers": {
    "ampworth": {
      "url": "https://ampworth.com/mcp"
    }
  }
}
VS Code .vscode/mcp.json

Add this to your project’s .vscode/mcp.json:

{
  "servers": {
    "ampworth": {
      "type": "http",
      "url": "https://ampworth.com/mcp"
    }
  }
}

These configurations are built from the information published by the author. Check the repository before installing a local server.

Our test

Responds The server speaks MCP and lists its tools.

Date
Nov 28, 2026, 09:00 (test run by L’Atlas)
Response time
751 ms (whole test)
Tools found
15
Announced name
ampworth 1.0.0
Protocol
MCP 2025-11-25
Next test
Dec 5, 2026
See the tools (15)
  • connection_route
    Work out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution network operator within 28 days, or apply and wait for approval before anything is con
  • get_document
    Fetch the full text of one guide, article or set of questions by its slug, as Markdown, not HTML. Slugs come from search_documents or list_documents. The answer carries the MCS documents the text draws on, and the ids of any calculators on
  • heat_pump_noise
    Calculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise limit, using the method in MCS 020. The formula is Lp = Lw + 10 log(Q / 4.pi.r^2) -
  • heat_pump_running_cost
    Compare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the household's own metered fuel use, not from a model, because a year of bills describes a
  • heat_pump_size
    Estimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to BS EN 12831, and nothing here replaces
  • hot_water_cylinder
    Work out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007. The demand is 45 litres a day for each of N, where N is the
  • list_calculators
    Lists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: the compass direction
  • list_documents
    Lists every document, optionally filtered by kind ('guide', 'article' or 'faq'), by category, or, for guides, by the reader they are written for. Guides are shelved by perspective: 'considering', 'buying', 'selling', 'installing' and 'learn
  • radiator_flow_temperature
    Work out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007. This is the calculation that decides whether a heat pump w
  • room_heat_loss
    Calculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in that room must be able to deliver. BS EN 12831 is a room-b
  • search_documents
    Search the guides, articles and questions for material on a UK home energy subject. Use this first, before answering from memory, whenever a question concerns UK heat pump or solar PV practice: how a system is sized, what a standard require
  • solar_pv_output
    Estimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certified installer to use. The method is: annual output = kWp x Kk x SF, where Kk is
  • solar_pv_self_consumption
    Estimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 003. The tables are not a model. They come from half-hourly monitoring of real B
  • solar_pv_shading
    Convert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful irradiance. An assessor stands at the mi
  • solar_pv_system_size
    Work out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill. This runs the MCS arithmetic backwards. The other solar calculators here each
Previous tests
Nov 28, 2026Responds751 ms15 tools
Nov 28, 2026Responds177 ms15 tools

What the test does: it opens an MCP session (initialize) and asks for the tool list (tools/list), with no key or account. No tool is ever called. Learn more

Cite this entry

For an article or comparison, use this permanent link and include the test date. The description comes from its source; reviews belong to members. A successful test is not a security audit.

Ampworth · L’Agora · Tested on

[Ampworth — L’Agora](https://lagora.dev/en/entry/com.ampworth/ampworth)

Sources, methodology and limitations

Comments

No comment yet. A question, a tip? Start the discussion.

Sign in to comment.

Is this your project? Sign in to claim this entry.

Badge for your README

com.ampworth/ampworth on L’Agora

Show that your project is listed (and tested, if it responds): paste this code in your README. The badge follows the latest test and links back to this entry.

Markdown (GitHub)

[![com.ampworth/ampworth on L’Agora](https://lagora.dev/badge/com.ampworth/ampworth.svg?lang=en)](https://lagora.dev/en/entry/com.ampworth/ampworth)

HTML

<a href="https://lagora.dev/en/entry/com.ampworth/ampworth"><img src="https://lagora.dev/badge/com.ampworth/ampworth.svg?lang=en" alt="com.ampworth/ampworth on L’Agora" height="20"></a>

Promote

For the entry’s author only: sign in to continue.

By the same author

Ampworth documents Responds

Ampworth calculators Responds

Report this entry