Future Micro Mold Lab
com.futuremicromoldllc/lab
Scientific-molding calculators: viscosity curve, gate seal, cavity balance, Cpk and gage R&R.
- Website
- www.futuremicromoldllc.com/lab/mcp
- Server address
https://www.futuremicromoldllc.com/api/mcp(streamable-http)- Version
- 1.0.0
- Author
- futuremicromoldllc.com (namespace verified by the registry)
- Source
- Official MCP registry (updated Nov 16, 2026)
How to install it
Claude Code
In a terminal:
claude mcp add --transport http lab https://www.futuremicromoldllc.com/api/mcpClaude (app and claude.ai)
Open Settings, then Connectors, and add a custom connector with this address. If the server asks you to sign in, Claude will walk you through it.
https://www.futuremicromoldllc.com/api/mcpChatGPT
In Settings, Apps & Connectors section, turn on developer mode, then create a connector with this address.
https://www.futuremicromoldllc.com/api/mcpCursor ~/.cursor/mcp.json
Add this to ~/.cursor/mcp.json (or .cursor/mcp.json in the project):
{
"mcpServers": {
"lab": {
"url": "https://www.futuremicromoldllc.com/api/mcp"
}
}
}VS Code .vscode/mcp.json
Add this to your project’s .vscode/mcp.json:
{
"servers": {
"lab": {
"type": "http",
"url": "https://www.futuremicromoldllc.com/api/mcp"
}
}
}These configurations are built from the information published by the author. Check the repository before installing a local server.
Our test
Responds The server speaks MCP and lists its tools.
- Date
- Nov 28, 2026, 08:55 (test run by L’Atlas)
- Response time
- 823 ms (whole test)
- Tools found
- 11
- Announced name
- future-micro-mold-lab 1.0.0
- Protocol
- MCP 2025-11-25
- Next test
- Dec 5, 2026
See the tools (11)
viscosity_curve
Find the optimal injection velocity from a velocity / peak-pressure sweep. Computes relative viscosity (plastic pressure times fill time) against relative shear rate, locates the shear-thinning plateau, and picks a velocity from the middlecavity_balance
Quantify cavity-to-cavity fill imbalance from short-shot weights. Give two or more replicate shots at a fill level and the result also says whether the variation comes from the cavities (runner and gate geometry) or from shot-to-shot procespressure_drop
Find where injection pressure is consumed along the flow path. Each reading is the CUMULATIVE peak pressure needed to fill through that section — an air shot gives the nozzle figure, then sprue, runner, gate and the full part — so the valuecosmetic_window
Map which combinations of two process parameters produce a cosmetically acceptable part, and how much room surrounds the center. Sweep wider than you expect the window to be: a passing point on the edge of the range tested means the windowgate_seal
Find the hold time at which the gate freezes and part weight stops rising. Seal is the first of three consecutive weights within 0.1% of each other that weight does not climb above afterwards; the recommended production hold time adds a marcooling_time
Find the shortest cooling time at which a dimension has stopped changing, and the cycle seconds that come off. Supply the drawing tolerance and the rule tightens to a tenth of it. Measure each part at a consistent interval after ejection —process_capability
Judge whether a running process can hold a dimension inside its tolerance. Reports Cp and Cpk from within-subgroup sigma and Pp and Ppk from overall sigma — the second pair is the overall figure many customer reports quote — each with a 95%gage_rr
Rate a measurement system from a crossed study: every operator measures every part, the same number of times. Two-way ANOVA per the AIAG Measurement Systems Analysis manual (4th ed.), matching Minitab's crossed gage R&R defaults: the operatget_study_protocol
Return the full procedure for one study: what it is for, the equipment needed, the step-by-step method at the press, and what a good result looks like, so the numbers collected at the press are the ones the calculation needs.plan_process_development
Given the studies already run, return the full development sequence with each one marked done or outstanding, what each fixes, what it depends on, and which study to run next. The order matters: each study fixes a setpoint the next one holdopen_study_sheet
Open an empty data sheet for one study in an interactive card: the procedure beside a table the person fills in or pastes into, with the result computed as they type. Also returns the procedure as text and a link to the same calculator on t
Previous tests
| Nov 28, 2026 | Responds | 823 ms | 11 tools |
| Nov 28, 2026 | Responds | 469 ms | 11 tools |
What the test does: it opens an MCP session (initialize) and asks for the tool list (tools/list), with no key or account. No tool is ever called. Learn more
Reviews
No review yet.
Sign in to leave a review. Your email is all you need.
Comments
No comment yet. A question, a tip? Start the discussion.
Sign in to comment.
Badge for your README
Show that your project is listed (and tested, if it responds): paste this code in your README. The badge follows the latest test and links back to this entry.
Markdown (GitHub)
[](https://lagora.dev/en/entry/com.futuremicromoldllc/lab)HTML
<a href="https://lagora.dev/en/entry/com.futuremicromoldllc/lab"><img src="https://lagora.dev/badge/com.futuremicromoldllc/lab.svg?lang=en" alt="com.futuremicromoldllc/lab on L’Agora" height="20"></a>For the entry’s author only: sign in to continue.