The Cable Code

io.github.exquad/thecablecode

Decode cables in 71 coding systems; design, rate, check, find equivalents; drums, laying, fire.

Website
thecablecode.com/developers
Server address
https://thecablecode.com/mcp (streamable-http)
Version
1.103.0
Author
exquad (namespace verified by the registry)
Source
Official MCP registry (updated Nov 27, 2026)

How to install it

Claude Code

In a terminal:

claude mcp add --transport http thecablecode https://thecablecode.com/mcp
Claude (app and claude.ai)

Open Settings, then Connectors, and add a custom connector with this address. If the server asks you to sign in, Claude will walk you through it.

https://thecablecode.com/mcp
ChatGPT

In Settings, Apps & Connectors section, turn on developer mode, then create a connector with this address.

https://thecablecode.com/mcp
Cursor ~/.cursor/mcp.json

Add this to ~/.cursor/mcp.json (or .cursor/mcp.json in the project):

{
  "mcpServers": {
    "thecablecode": {
      "url": "https://thecablecode.com/mcp"
    }
  }
}
VS Code .vscode/mcp.json

Add this to your project’s .vscode/mcp.json:

{
  "servers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp"
    }
  }
}

These configurations are built from the information published by the author. Check the repository before installing a local server.

Our test

Responds The server speaks MCP and lists its tools.

Date
Nov 28, 2026, 10:47 (test run by L’Atlas)
Response time
797 ms (whole test)
Tools found
25
Announced name
thecablecode 1.103.0
Protocol
MCP 2025-11-25
Next test
Dec 5, 2026
See the tools (25)
  • decode_cable_code
    Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Dete
  • design_cable
    Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its standard and source, diameter, weight, designation, current, voltage drop and short-c
  • find_equivalents
    The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equivalent, close (the differences) or none (the reason). Deterministic, no LLM; neve
  • overhead_conductor
    A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code ("242-AL1/39-ST1A", EN 50182; "401-AL0/28-MEHST", FprEN 50540) or an EN 50182 Annex F table ("F.19"): stranding, areas, diameters, mass, strength and resistance as printed,
  • check_cable
    Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a
  • extract_datasheet
    Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and smallest thickness, screen, armour, diameters and standards, with page and row.
  • read_tender
    Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing sections, with pages. An LLM (Claude) copies values, deciding nothing. Waits up
  • write_specification
    Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender order (Markdown and text) and the required / offered schedule (CSV and JSON), RE
  • design_presets
    What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, its designation, voltage, cores, section and metal; and spec_standards[], the fa
  • drum_fit
    Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic K, DIN, Spanish, NEMA, Turkish, IS 10418 and makers' drums with sources, with ba
  • burial_depth
    Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rule with its source and seen level, or null with the reason. Free, no LLM. Notes:
  • fire_class
    The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenum ...), the rule lines with sources and seen levels; the US NEC Article 722 list
  • awg_metric
    AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation constant in MΩ·km. Send awg or mm2, metal Cu (default) or Al. Free, no LLM. Note
  • conduit_fill
    NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, against Table 1's fill limits, with the jam ratio; each area with its table. Free
  • pull_cable
    Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the allowable values with sources. $0.50 USDC per calculation (x402); the verdict al
  • tray_fill
    NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 ca
  • drum_loading
    How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. Choose the drum with drum_fit (free). $0.50 USDC per calculation (x402); the ver
  • cold_weather_check
    A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknown. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://g
  • mv_electrical
    MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://
  • economic_size
    Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecab
  • commissioning_sheet
    The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to record results in. $0.50 USDC per calculation (x402), no free allowance. Notes: theca
  • cable_prep
    End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kinds, outdoor creepage (IEC TS 60815-3), glands and cleats. $0.50 USDC per calculat
  • iec60287_rating
    IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency ratings, banks, troughs, crossings. $5.00 USDC per calculation (x402), no free allowan
  • degassing_time
    Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Note
  • equivalence_report
    An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a statement of interchangeability. $0.50 USDC per calculation (x402), no free allowan

What the test does: it opens an MCP session (initialize) and asks for the tool list (tools/list), with no key or account. No tool is ever called. Learn more

Reviews

No review yet.

Sign in to leave a review. Your email is all you need.

Comments

No comment yet. A question, a tip? Start the discussion.

Sign in to comment.

Is this your project? Sign in to claim this entry.

Badge for your README

io.github.exquad/thecablecode on L’Agora

Show that your project is listed (and tested, if it responds): paste this code in your README. The badge follows the latest test and links back to this entry.

Markdown (GitHub)

[![io.github.exquad/thecablecode on L’Agora](https://lagora.dev/badge/io.github.exquad/thecablecode.svg?lang=en)](https://lagora.dev/en/entry/io.github.exquad/thecablecode)

HTML

<a href="https://lagora.dev/en/entry/io.github.exquad/thecablecode"><img src="https://lagora.dev/badge/io.github.exquad/thecablecode.svg?lang=en" alt="io.github.exquad/thecablecode on L’Agora" height="20"></a>

Promote

For the entry’s author only: sign in to continue.

Report this entry