tech.novtriq/engineering
27 engineering compliance and calculation tools for the built environment (UK, EU, UAE).
- Website
- novtriq.tech/
- Server address
https://api.novtriq.tech/mcp(streamable-http)- Version
- 1.0.0
- Author
- novtriq.tech (namespace verified by the registry)
- Source
- Official MCP registry (updated Jul 26, 2026)
How to install it
Claude Code
In a terminal:
claude mcp add --transport http engineering https://api.novtriq.tech/mcpClaude (app and claude.ai)
Open Settings, then Connectors, and add a custom connector with this address. If the server asks you to sign in, Claude will walk you through it.
https://api.novtriq.tech/mcpChatGPT
In Settings, Apps & Connectors section, turn on developer mode, then create a connector with this address.
https://api.novtriq.tech/mcpCursor ~/.cursor/mcp.json
Add this to ~/.cursor/mcp.json (or .cursor/mcp.json in the project):
{
"mcpServers": {
"engineering": {
"url": "https://api.novtriq.tech/mcp"
}
}
}VS Code .vscode/mcp.json
Add this to your project’s .vscode/mcp.json:
{
"servers": {
"engineering": {
"type": "http",
"url": "https://api.novtriq.tech/mcp"
}
}
}These configurations are built from the information published by the author. Check the repository before installing a local server.
Our test
Responds The server speaks MCP and lists its tools.
- Date
- Nov 28, 2026, 09:07 (test run by L’Atlas)
- Response time
- 553 ms (whole test)
- Tools found
- 27
- Announced name
- novtriq-engineering 3.0.0
- Protocol
- MCP 2025-06-18
- Next test
- Dec 5, 2026
See the tools (27)
calculate_pue
Calculate Power Usage Effectiveness (PUE) for a data centre or server room. Returns PUE score, efficiency rating, annual cost estimate, and engineering recommendations.check_nis2_readiness
Assess NIS2 Directive (EU 2022/2555) compliance readiness. Returns compliance score (0-18), maturity level, estimated fine exposure, and prioritised remediation actions.assess_epbd_score
Assess EU EPBD (2024) compliance. Returns compliance score, renovation cost estimate, deadline pressure, and priority retrofit measures.estimate_cooling_load
Estimate cooling load using CIBSE Guide B2 / ASHRAE methodology. Returns required capacity, installed capacity with redundancy, system recommendation, and annual energy.check_uae_bim_compliance
Check UAE BIM mandate applicability (Dubai Circular 196, Abu Dhabi DMT, Sharjah). Returns mandate status, compliance score, required LOD, and submission checklist.check_uae_cybersecurity
Assess UAE cybersecurity regulatory compliance (NESA IAS, Dubai ISR, CBUAE, TDRA). Returns applicable framework, compliance score, critical gaps, and mandatory controls.check_grid_feasibility_uae
Assess UAE grid connection feasibility (DEWA/ADDC/SEWA/FEWA). Returns feasibility score, connection timeline, recommended voltage, substation requirement, and next steps.get_technical_dd_quote
Generate an indicative Technical Due Diligence (TDD) fee estimate. Returns preliminary and full DD fee ranges (GBP), turnaround days, and contact CTA.calculate_carbon
Calculate operational + embodied carbon and net-zero gap (CIBSE TM65 / RICS WLCA). Returns carbon intensity, benchmark, and prioritised reduction measures with payback.thermal_load
Thermal Load Estimator for data centres / critical facilities. Returns total heat load, cooling capacity, units, airflow, chiller size, PUE estimate, power density, and a CRAC/CRAH/DLC/immersion comparison.roi_calculator
Engineering ROI calculator. Returns current manual cost, annual saving, net benefit, ROI %, payback months, 3-year NPV and a verdict.building_carbon_footprint
Building carbon footprint (Scope 1/2/3) with CRREM stranding check and embodied carbon. Returns per-scope tCO2e, intensity, CRREM compliance, net-zero gap and priority actions.building_readiness
Building Readiness assessment for change-of-use / conversion. Returns a 0-100 readiness score, project complexity, four domain scores (structural, MEP, compliance, digital/BIM) with RAG, and recommendations.eurocode_beam_designer
Preliminary Eurocode beam design (steel EC3 / composite / reinforced concrete EC2). Selects a section, computes ULS bending & shear utilisation, SLS deflection, and fire protection. Indicative, not a stamped design.eurocode_column_checker
Eurocode axial column buckling check (steel EC3 6.3.1 flexural buckling / RC EC2 5.8 simplified). Returns Ncr, non-dimensional slenderness, reduction factor chi, NRd and utilisation. Indicative, not a stamped design.eu_cost_benchmarking
Parametric construction cost benchmark across UK/EU/GCC by country, project type, specification, procurement, programme and BIM. Returns per-m2 and total cost ranges plus a cost breakdown. Indicative parametric estimate, validate against cudgnb_bim_readiness
DGNB certification pre-score and BIM (ISO 19650) maturity self-assessment from a 20-question checklist. Returns pre-score, achievable certification level, BIM level, domain breakdown and prioritised gaps. Not a formal DGNB audit.contractor_vetting
NIS2 / EPBD contractor vetting score from a 12-question checklist across financial, technical, cyber (NIS2) and energy (EPBD) categories. Flags blocking (critical) failures and returns recommended additional checks. Not a formal due-diligendigital_renovation_passport
EPBD-style staged digital renovation passport: 3-phase roadmap (quick wins, system upgrades, deep renovation) with cost ranges, energy savings and EPC trajectory from current EPC, floor area and heating type. Indicative.uk_planning_checker
UK permitted-development (GPDO 2015, England) rules engine for extensions, loft conversions and change of use. Returns a verdict (likely_pd / requires_permission / complex), applicable PD class, conditions and flags (listed building, Articlpart_s_ev
UK Approved Document S 2021 electric-vehicle charge-point requirement calculator for new build and major renovation, residential and non-residential. Returns required charge points, cable routes (1-in-5 for non-residential), minimum power apart_o_overheating
UK Approved Document O 2021 simplified-method overheating check for new residential: tests maximum glazing area (by orientation, risk zone, cross vs single aspect) and minimum free ventilation area. Returns pass/fail and points to CIBSE TM5mees_checker
England & Wales Minimum Energy Efficiency Standard (MEES) check for private rented property. Tests against the in-force EPC E minimum (domestic and non-domestic) and surfaces the PROPOSED (not yet law) EPC C / 2030 uplift as an advisory onlheatpump_heatloss
Domestic whole-dwelling fabric + ventilation heat-loss estimate for heat pump sizing (BS EN 12831 / MCS), from floor area, storeys, age band, location and glazing. Returns design heat loss (kW), recommended heat pump output, indicative SCOPeed_datacentre_pack
EU Energy Efficiency Directive data-centre reporting pack (Dir (EU) 2023/1791 Art.12 + Del. Reg (EU) 2024/1364). Determines reporting scope (IT power >= 500 kW) and computes the mandated KPIs PUE, WUE, ERF and REF. Note: the regulation manduae_climate_ghg
UAE Scope 1 + Scope 2 GHG estimate from electricity and gas use, with emirate-specific grid emission factors (Dubai/Abu Dhabi/national) and the Federal Decree-Law No. 11 of 2024 mandatory-reporting context. Grid factors carry base-year/confsap_sbem_precheck
UK SAP 10.3 / SBEM EPC precheck. Maps a known SAP rating (1-100) to its EPC band, and/or computes annual CO2 and primary energy from fuel consumption using validated SAP 10 fuel factors. The official EPC band is cost-based and needs a full
What the test does: it opens an MCP session (initialize) and asks for the tool list (tools/list), with no key or account. No tool is ever called. Learn more
Reviews
No review yet.
Sign in to leave a review. Your email is all you need.
Comments
No comment yet. A question, a tip? Start the discussion.
Sign in to comment.
Badge for your README
Show that your project is listed (and tested, if it responds): paste this code in your README. The badge follows the latest test and links back to this entry.
Markdown (GitHub)
[](https://lagora.dev/en/entry/tech.novtriq/engineering)HTML
<a href="https://lagora.dev/en/entry/tech.novtriq/engineering"><img src="https://lagora.dev/badge/tech.novtriq/engineering.svg?lang=en" alt="tech.novtriq/engineering on L’Agora" height="20"></a>For the entry’s author only: sign in to continue.