Flow Pack
io.github.Nero-Engine/flow-pack
Live heat pump planning checks and flood warnings, pipe and heat sizing, gas records for plumbers
Description fournie par l’auteur dans le registre officiel MCP (en anglais).
- Dépôt
- github.com/Nero-Engine/flow-pack-mcp
- Site
- flow-pack.nerolabs.workers.dev/docs
- Adresse du serveur
https://flow-pack.nerolabs.workers.dev/mcp(streamable-http)- Version
- 1.2.0
- Auteur
- Nero-Engine (espace de noms vérifié par le registre)
- Source
- Registre officiel MCP (mis à jour le 27 nov. 2026)
Comment l’installer
Claude Code
Dans un terminal :
claude mcp add --transport http flow-pack https://flow-pack.nerolabs.workers.dev/mcpClaude (application et claude.ai)
Ouvrez Réglages, puis Connecteurs, et ajoutez un connecteur personnalisé avec cette adresse. Si le serveur demande une connexion, Claude vous la proposera.
https://flow-pack.nerolabs.workers.dev/mcpChatGPT
Dans Réglages, partie Applications et connecteurs, activez le mode développeur, puis créez un connecteur avec cette adresse.
https://flow-pack.nerolabs.workers.dev/mcpCursor ~/.cursor/mcp.json
Ajoutez ceci au fichier ~/.cursor/mcp.json (ou .cursor/mcp.json dans le projet) :
{
"mcpServers": {
"flow-pack": {
"url": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}VS Code .vscode/mcp.json
Ajoutez ceci au fichier .vscode/mcp.json de votre projet :
{
"servers": {
"flow-pack": {
"type": "http",
"url": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}Ces configurations sont construites à partir des informations publiées par l’auteur. Vérifiez le dépôt avant d’installer un serveur local.
Notre test
Répond Le serveur répond au protocole MCP et liste ses outils.
- Date
- 28 nov. 2026, 10:10 (test fait par L’Atlas)
- Temps de réponse
- 277 ms (test complet)
- Outils trouvés
- 10
- Nom annoncé
- nerolabs-flow-pack 1.2.0
- Protocole
- MCP 2025-06-18
- Prochain test
- 5 déc. 2026
Voir les outils (10)
list_capabilities
Lists Flow Pack's tools, what it covers (nations, pipe materials, gases, record types, emergency situations) and what it deliberately does not do. Free, needs no input.size_pipe
Sizes a hot or cold water pipe, or a low-pressure gas pipe, and shows the working. Water: design flow (from outlets, with a simple in-use-at-once rule, or a flow you give), velocity against a limit (1.5 m/s default), pressure loss per metresize_heat_source
Works out the heat loss of each room (fabric U x A x delta T plus ventilation 0.33 x air changes x volume x delta T) and the total, then sizes a combi, system or regular boiler, or a heat pump, to the nearest common size. Combi sizing alsosize_radiators
For each room's heat loss, works out the rated (delta T 50) radiator output needed at the system's flow and return temperatures, using output = rated x (mean water to air difference / 50) ^ 1.3. Shows how far an existing radiator falls shorcheck_notifiable_work
For plumbing and heating jobs in England or Wales: does it need a Gas Safe registered engineer, an unvented (G3) qualified installer, building regulations notification (Approved Documents G, J, L and others) and a water company notice (Watecheck_gas_record
Checks a filled landlord gas safety record (CP12) or a boiler commissioning record and lists errors and warnings: missing required fields, failed tightness, flue, ventilation or safety device checks, CO/CO2 ratio over the limits, gas rate oemergency_triage
For a homeowner reporting a problem: the safe first steps to do now, what not to do, who to call first (the gas emergency service 0800 111 999 for a gas smell or CO alarm), whether it is a real emergency, and an `urgency` value of routine,property_check
Looks up, live from official open data, what applies at the customer's postcode before an air source heat pump, a new boiler flue or external pipework: listed buildings, conservation areas, Article 4 directions, World Heritage Sites, Nationflood_warnings
Reads the Environment Agency real time flood warning service (England, updated every 15 minutes) for flood alerts, flood warnings and severe flood warnings near the customer's postcode, and says what to tell the customer: flood water or a ptrade_profile
Checks the business's own details (Nero Trade Profile v1: trading name, Companies House number, registration scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registratio
Ce que fait le test : il ouvre une session MCP (initialize) et demande la liste des outils (tools/list), sans clé ni compte. Aucun outil n’est appelé. En savoir plus
Avis
Pas encore d’avis.
Connectez-vous pour donner votre avis. Il suffit de votre e-mail.
Commentaires
Pas encore de commentaire. Une question, une astuce ? Lancez la discussion.
Connectez-vous pour commenter.
C’est votre projet ? Connectez-vous pour revendiquer la fiche.
Badge pour votre README
Montrez que votre projet est référencé (et testé, s’il répond) : collez ce code dans votre README. Le badge suit le dernier test et renvoie vers cette fiche.
Markdown (GitHub)
[](https://lagora.dev/fiche/io.github.nero-engine/flow-pack)HTML
<a href="https://lagora.dev/fiche/io.github.nero-engine/flow-pack"><img src="https://lagora.dev/badge/io.github.nero-engine/flow-pack.svg" alt="io.github.Nero-Engine/flow-pack sur L’Agora" height="20"></a>Réservé à l’auteur de la fiche : connectez-vous pour continuer.
Du même auteur
Homeowner Pack Répond
Handyman Pack Répond
AI Citation Finder Clé requise
Google Rank Tracker Clé requise